The application of muon tomography to the imaging of railway tunnels. Pdf the application of muon tomography to the imaging of. Cosmic rays are a form of highenergy radiation that originate from. Design and characterization of a small muon tomography. Muon scans confirm complete reactor meltdown at fukushima.
Mar 31, 2017 we present an underground cosmic ray muon tomographic experiment imaging 3d density of overburden, part of a joint study with differential gravity. In order to gain information about the threedimensional scattering field with which the muon interacts before it reaches the detector, the direction that each muon is traveling after it exits the tissue sample must be known. Mt is a techinique in development geared towards detecting nuclear material in vehicles, cargo freight and general mobile containers crossing security checkpoints. The fact that both trackers have the same trend is likely a coincidence. Muons, subatomic particles, are produced continuously and naturally in the earths upper atmosphere, and there is a constant flow of them to the earths surface. Those studies were performed as the first in a series to assess the feasibility of this technology and image reconstruction techniques in. Novel muon imaging techniques philosophical transactions. Muon tomography is a technique that uses cosmic ray muons to generate threedimensional images of volumes using information contained in the coulomb scattering of the muons. The dominant muon decay mode sometimes called the michel decay after louis michel is the simplest possible. Muon tomography applied to a dense uranium deposit at the. Limitations arise from inversion ambiguities, access locations, and statistics 40. Mar 20, 2003 the test object is a tungsten cylinder radius, 5.
The points a,b,c and d are the positions of muon in these detectors respectively, and other informationis shown in the. The signal obtained from one projection or view is not enough to reconstruct an. Our main field of research is experimental high energy physics hep. Muon tomography is a useful method for monitoring special nuclear materials snms because it can provide effective information on the presence of highz materials, has a high enough energy to deeply penetrate large amounts of shielding, and does not lead to any health risks and danger above background.
We demonstrate the validity of muon tomographic imaging with data acquired at a depth of about 600 m underground. Pdf in this article on muon tomography we report our work on the development of an. Cmspho muon 20170021 small, medium, large, original the mst scanner at the infn national laboratory of photograph. Muon tomography offers the chance to develop a much cheaper, continuous and passive monitoring system for deep subsurface storage sites. In this article on muon tomography we report our work on the development of an intelligent pattern detection system for materials with high atomic numbers z for homeland security application. A plastic scintillatorbased muon tomography system with an integrated muon spectrometer author links open overlay panel v. Muon tomography is a technique that uses information contained in the coulomb scattering of cosmic ray muons to generate three dimension images of volumes between tracking detectors.
The cosmic ray muon has a broad angular distribution around zenith with limited. By optimizing the limited angle data, however, image resolution can be improved. Since muons are much more deeply penetrating than xrays, muon tomography can be used to image through much thicker material than xray based tomography such as ct scanni. This method, muon scattering tomography mst, was proposed in 2003. Muon scanning finds hidden chamber in great pyramid of giza. D density inversion of a uranium deposit using muon tomography. Jul 28, 2014 see, the reactor core is mostly empty space at this point, and the resolution of socalled muon stop tomography is too low to show the positions of individual objects in a room. Muography of different structures using muon scattering and. Compton imaging tomography cit february 29, 2012 7 xray source slit collimator intensified xray camera defect void data to computer compton scattered xrays xray imaging optics aperture composite or multilayer material planar x ray beam needs only 1d scanning due to using a 2d beam higher scanning speed. Muon tomography imaging improvement using optimized. Image resolution of muon tomography is limited by the range of zenith angles of cosmic ray muons and the flux rate at sea level.
The tungsten cylinder and the iron in the rails are. Using muons from cosmic rays to find fraying infrastructure. Muon geotomography imaged a known massive sulfide deposit in a complex geological environment. Burns atomic weapons establishment uk this talk will report an overview of current progress in the area of cosmic ray muon scattering tomography mst to infer measurements of material properties for nuclear securityrelated applications. Z sr1 cm2 min1, where n is the number of tracks detected. In reality, muons ionize solid material as they pass through, losing energy and possibly scattering in the process. As with other leptons, the muon is not known to have any substructure that is, it is not thought to be composed of any simpler particles. One of the salient features of muon tomography is that the cosmic rays are produced by supernova explosions light years away, providing a free, natural, and continual source for 3d density imaging. The measured cosmic ray rate, in both the horizontal and vertical viewing modes, are plotted in fig. Muon tomography mt one of the latest innovation in nuclear detection being developed is muon tomography mt. The tech that revealed a hidden chamber inside egypts great. Muon tomography algorithms for nuclear threat detection. Tomographic imaging techniques using the coulomb scattering of cosmicray muons have been shown previously to successfully identify and characterise low and highz materials within an air matrix using a prototype scintillatingfibre tracker system. Muon tomography imaging improvement using optimized limited.
Muography of different structures using muon scattering. Muon tracing and image reconstruction algorithms for. A major source of uncertainty in muon tomography is the assumption that the muon trajectory is constant, that is, that the direction determined at the detector is a valid estimate of the direction from which the muon ultimately came. The muon tomography survey summarized in this article was performed at the mcarthur river mine. Clarifying how muon tomography works, ria novosti explained that as cosmic raygenerated particles find their way into the earths atmosphere 40 km and below, they collide with. Cmsphomuon20170021 small, medium, large, original the mst scanner at the infn national laboratory of photograph.
Integrating over the upper hemisphere gives a total. Simulation study of muon scattering for tomography. International audiencethe cosmic ray muon tomography gives an access to the density structure of geological targets. Pdf during the last 15 years muonbased imaging, or muography, has. Exploded view of scintillator panel assembly left and configurable frame. Review of possible applications of cosmic muon tomography infn. We present an underground cosmic ray muon tomographic experiment imaging 3d density of overburden, part of a joint study with differential gravity. A plastic scintillatorbased muon tomography system with. This technique has recently been generalized to provide threedimensional information about samples in a method known as muon tomography. Application of muon tomography to encapsulated nuclear waste. One widely used technique employs the multiple coulomb scattering properties of cosmic muons in matter. Advantages of this technique are the muons ability to penetrate significant overburden and the absence of any additional dose beyond the natural cosmic ray flux.
Both the muon absorption and multiple scattering imaging methods measure muon tracks on an eventbyevent basis, therefore, it is possible to form muon quasibeams by using the measured muon tracks. Bonal, rowe, and guardincerri describe how muon imaging can improve the resolution of other near. Find, read and cite all the research you need on researchgate. Muon tomography offers an alternative which is both continuous and potentially much less expensive. The ray signal, the angle of mcs is, the multiple coulomb scattering is stochastic with a.
Methods and simulations of muon tomography and reconstruction. Since muons are much more deeply penetrating than xrays, muon tomography can be used to image through much thicker material than xray based tomography such as ct scanning. A group of scientists from egypt, japan, canada, and france just teamed up to scan egypts pyramids in an effort to reveal one of earths longest secrets. Pdf on oct 10, 2011, kristofer davis and others published joint 3d inversion of muon tomography and gravity data find, read and cite all the research you need on researchgate.
Currently, muon tomography can resolve features to the submeter scale. Uob will lead wp4, the muon tomography work package. Mcs tomography at the infn national laboratory of legnaro padova a demonstrator for the study of muon radiography has been assembled using two spare muon chambers detectors produced for cms and installed in the barrel two drift chambers 2. Muon tomography has already been successfully used to image deep structures such as the interior of volcanoes and pyramids. In the present article we describe a muon telescope adapted to harsh environmental conditions.
Message from the organizing editor of this fasttimes issue. In the late 1960s, a team led by nobelwinning physicist luis alvarez used muon detectors pdf to scan for undiscovered rooms in the pyramid of khafre, the great pyramids slightly smaller. Inverted 3d density images of the deposit are similar to a model derived from drill data. The recentlydeveloped muon tomography method interestingly reinforces gravity methods by. Looking inside dangerous places find, read and cite. Postdoctoral research associate on cms experiment aug 2019. Muon tomography is a noninvasive imaging technique which can be used to visualize the internal structures of an object using the coulomb scattering of cosmicray muons.
The recentlydeveloped muon tomography method interestingly reinforces gravity methods by providing. The energy spectrum of each muon quasibeam should reflect the energy spectrum of the cosmic ray muon. Since muons have much stronger penetrating power than xrays, muon tomography is often used to image through much thicker materials than xray tomography, i. Low flux rate limits the use of advanced data rebinning and processing techniques to improve image quality. The curve plotted as a solid line has been fitted to the data and is given by. Imaging tissue structures using muon tomography practice. Review of possible applications of cosmic muon tomography. A short description of the muon tomography demonstrator at the infn.
Progress in muon tomography germano bonomi figure 2. Since its development in the 1950s, muon tomography has taken many forms, the most important of which are muon transmission radiography and muon scattering tomography. The cosmic ray muon tomography technique can provide a solution to this problem, by be ing able to discriminate between highz materials and hence to distinguish ssile material from the highz shielding. When the particles hit a highdensity object, such as magma, they lose energy or are absorbed. A plastic scintillatorbased muon tomography system with an. From our point of view he physicists there are several. Antimuons, in mirror fashion, most often decay to the corresponding antiparticles. Many of these particles are muons, secondgeneration leptons that are produced by cosmic rays and reach earths surface at a rate of 1 per square centimeter per minute. Aug 21, 2014 the technique is called muon imaging, or muon tomography. Muon flux simulations initial studies 2010 indicates that by instrumenting m2 and taking data for 1 year then 0. Only the most prominent applications are discussed in the following section. In this article on muon tomography we report our work on the development of an intelligent pattern detection system for. Geological exploration and tomography wittcos c ay uos eh. Simulation study of muon scattering for tomography reconstruction.
Muon tomography every second of every day, we are bombarded with thousands of particles that pass through our bodies without us noticing. Inferences about subsurface structures from observed muon flux i. Ultimately, the measured hit detection efficiency is more than sufficient for pursuing muon tomography investigations. In particular uob will be responsible for delivering the rpc detector system. We will contribute to all subtasks of the work package. This movie is part of geoparticles interface project, which is included in the univearths. History 1924 mathematical theory of tomographic image. The trackers use a form of muon tomography, the technique using cosmic raygenerated muon particles, to radiograph underground objects and geological structures.
Hypothetic path of a muon inside the inspected volume. Using muons to image the subsurface sandia national laboratories. Hit detection efficiency for the upper and lower trackers. See, the reactor core is mostly empty space at this point, and the resolution of socalled muon stop tomography is too low to show the positions of individual objects in a room. What is muon tomography and how does it help finding cavity. Jun 30, 2015 the images obtained from muon tomography lag behind ultrasound or xray analysis in resolution, but the techniques could be particularly effective when used in conjunction with each other. Because of their high penetrative power of high energy muons, this technique can potentially be used to image large and dense objects. Novel muon imaging techniques philosophical transactions of. Characterising encapsulated nuclear waste using cosmicray. Carbon storage could play a major part of uk and global environmental policies to tackle global warming but still allow us to generate clean, affordable energy. Russian scientists invent device allowing them to see. The technique, muon tomography, is similar to ct scanning in medical imaging, but as muons are more penetrating than xrays much larger and deeper structures can be imaged. Coulomb scattering of cosmic ray muons to create tomographic images of volumes.
What is muon tomography and how does it help finding. Tomuvolinternational audiencetheir long range in matter renders highenergy atmospheric muons a unique probe for geophysical explorations, permitting the cartography of density distributions which can reveal spatial and possibly also temporal variations in extended geological structures. Pdf muon tomography algorithms for nuclear threat detection. Nagoya university japan, kek high energy accelerator research organization tsukuba japan and cea. Probing fukushima with cosmic rays should speed cleanup. Muon tomography mt, based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles, is a promising technique for. Further, the volume of rock interrogated by borehole muon detectors is an order of magnitude larger than the volume from a fence of drill holes. Design and operation of a field telescope for cosmic ray. It has been demonstrated in our previous study that this technique is capable of. The images obtained from muon tomography lag behind ultrasound or xray analysis in resolution, but the techniques could be particularly effective when used in conjunction with each other. Horizontal cosmic ray muon radiography for imaging nuclear. We present a qualitative assessment of the radiographic imaging and 3. The technique is called muon imaging, or muon tomography.
1143 598 254 784 608 1534 1658 1645 915 1386 1132 1461 32 1087 1649 1193 174 26 79 1562 499 1057 507 1455 857 246 1070 140 1431 301 276 292 1591 1442 1480 79 82 22 736 197 1135 159 46 110